Built for any type of environment, from desert heat and dust to freezing cold and rain, ODI's VSMC give consistent, year-round dependable service. A simple adjustment of the frequency setting varies flow rate and pump discharge pressure to match your changing reservoir conditions, eliminating costly system change-outs over the life of the well.
Specifications

Input................................................460 volts (±10%), 3 phase
Line Frequency..............................................................58-62 Hz
Output...................................................40-480 volts, 10-120 Hz
Efficiency.....................................................> 98% at rated load
Volts/Hertz ratio...................................................................7-10
Waveshape....................................................................Six step
Voltage boost.............................................................0-200 VAC
Minimum speed..................................................................10 Hz
Maximum speed...............................................................120 Hz
Accel / Decel...............................................................3-200 SEC.
Frequency stability.....................................................±0.1 Hertz
Control power ride-through............................................3 cycles
Torque limit....................................Adjustable 50-100% full load
Altitude...........................................................................5000 ft.
Overload current............................150% 0-150% of VSC Rating
Stop mode................................................Controlled declaration
Short-circuit protection.......................................Phase to phase
Ground fault protection................Phase to ground short circuits
Instantaneous overcurrent (IOT).......................................170%
Overtemp. protection........................Thermostatically controlled
Regeneration protection...............Torque limit and regeneration override
Control circuit power.........................................................24v dc
Operating temperature....................Nema 1: 32°F to 102°F
Nema 2: 32°F to 122°F
W/Heater: -40°F to 122°F
Storage temperature......................................... -76°F to 158°F
Humidity................................Nema 1: to 95% noncondensing
Nema 3: Suitable for use outdoors